A compact setup for loading magneto-optical trap in ultrahigh vacuum environment
arXiv:2206.13271
Abstract
We have developed a compact setup which enables loading a magneto-optical trap (MOT) in ultra-high vacuum (UHV) environment. Nearly atoms of are trapped in the MOT at Torr base pressure in the chamber. After the MOT loading, we have successfully demonstrated working of quadrupole magnetic trap in this chamber with a lifetime of s
9 pages, 4 figures