paper

Determination of hydrogen concentration in solids by transmission ERDA under nuclear-elastically enhanced recoiling of H by 8 and 9 MeV He

arXiv:2206.02387 · doi:10.1088/1361-648X/ac8b4e

Abstract

Hydrogen concentrations in thin self-supporting samples of polyphenylene sulfide and muscovite have been determined by nuclear-elastic recoil detection analysis of transmission layout. The analysis procedure is based only on the database of stopping power and recoil cross section for material analysis, without using any reference sample of known H content. For the polyphenylene sulfide sample, the determined value of cm is in good agreement with the calculated value of cm. For the muscovite sample, the H concentration originating each from bound water and absorbed water is uniform over the entire thickness of the sample. The determined concentration Hcm of the muscovite agrees excellently with the value of Hcm obtained from other quantitative analyses typically applied for minerals. The present results demonstrate the capability of accurate determination of H contents in materials and minerals by transmission ERDA.

15 pages, 6 figures

References in corpus (1)