Study of neutron irradiation effects in Depleted CMOS detector structures
arXiv:2112.10738 · doi:10.1088/1748-0221/17/03/P03030
Abstract
In this paper results of Edge-TCT and I-V measurements with passive test structures made in LFoundry 150 nm HV-CMOS process on p-type substrates with different initial resistivities ranging from 0.5 to 3 kcm are presented. Samples were irradiated with reactor neutrons up to a fluence of 210 n/cm. Depletion depth was measured with Edge-TCT. Effective space charge concentration was estimated from the dependence of depletion depth on bias voltage and studied as a function of neutron fluence. Dependence of on fluence changes with initial acceptor concentration in agreement with other measurements with p-type silicon. Long term accelerated annealing study of and detector current up to 1280 minutes at 60C was made. It was found that and current in reverse biased detector behaves as expected for irradiated silicon.