Comprehensive technology study of radiation hard LGADs

arXiv:2111.06731 · doi:10.1088/1742-6596/2374/1/012175

Abstract

Towards radiation tolerant sensors for pico-second timing, several dopants are explored. Using a common mask, CNM produced LGADs with boron, boron + carbon and gallium implanted gain layers are studied under neutron and proton irradiation. With fluences ranging from to on both particle species, reported results focus on acceptor removal and gain reduction via electrical characterization. Timing performance, charge collection, gain and relative efficiency are treated through charged particle measurements, including signal analysis and noise characterization. An accent is placed on stability, via dark rate and operating voltage studies while, radiation related gain reduction mechanisms are examined comparing gain estimations through different approaches.

TIPP2021 Conference Proceedings, May 27th 2021