Low mechanical loss TiO:GeO coatings for reduced thermal noise in Gravitational Wave Interferometers
arXiv:2108.04954 · doi:10.1103/PhysRevLett.127.071101
Abstract
The sensitivity of current and planned gravitational wave interferometric detectors is limited, in the most critical frequency region around 100 Hz, by a combination of quantum noise and thermal noise. The latter is dominated by Brownian noise: thermal motion originating from the elastic energy dissipation in the dielectric coatings used in the interferometer mirrors. The energy dissipation is a material property characterized by the mechanical loss angle. We have identified mixtures of titanium dioxide (TiO) and germanium dioxide (GeO) that show internal dissipations at a level of 1 , low enough to provide almost a factor of two improvement on the level of Brownian noise with respect to the state-of-the-art materials. We show that by using a mixture of 44% TiO and 56% GeO in the high refractive index layers of the interferometer mirrors, it would be possible to achieve a thermal noise level in line with the design requirements. These results are a crucial step forward to produce the mirrors needed to meet the thermal noise requirements for the planned upgrades of the Advanced LIGO and Virgo detectors.
References in corpus (7)
- Advanced Virgo: a 2nd generation interferometric gravitational wave detector
- Advanced LIGO
- Sensitivity and Performance of the Advanced LIGO Detectors in the Third Observing Run
- Prospects for doubling the range of Advanced LIGO
- Multi-Material Coatings with Reduced Thermal Noise
- Optical and mechanical properties of ion-beam-sputtered NbO and TiO-NbO thin films for gravitational-wave interferometers
- A method for the experimental measurement of bulk and shear loss angles in amorphous thin films