Personal Dosimetry in Direct Pulsed Photon Fields with the Dosepix Detector
arXiv:2106.06714 · doi:10.1109/TNS.2022.3222544
Abstract
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of pulse duration at a nearly constant dose rate of about 3.7Sv/h shows a flat response around 1.0 from 3.6s down to 2ms. A response close to 1.0 is achieved for dose rates from 0.07Sv/h to 35Sv/h for both pixel sizes. Above this dose rate, the large pixels (220m edge length) are below the lower limit. The small pixels (55m edge length) stay within limits up to 704Sv/h. The count rate linearity is compared to previous results, confirming the saturating count rate for high dose rates.
6 pages, 4 figures. This work was accepted for publication in IEEE Transactions on Nuclear Science