Compact Spectroscopy of keV to MeV X-rays from a Laser Wakefield Accelerator
arXiv:2103.01370 · doi:10.1038/s41598-021-93689-5
Abstract
We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 7.5 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to >100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.
References in corpus (8)
- Femtosecond x rays from laser-plasma accelerators
- All-optical Compton gamma-ray source
- Hard X-rays from laser-wakefield accelerators in density tailored plasmas
- Ultra-Intense Gamma-Rays Created Using the Texas Petawatt Laser
- An all-optical Compton source for single-exposure X-ray imaging
- Measuring fast electron spectra and laser absorption in relativistic laser-solid interactions using differential bremsstrahlung photon detectors
- Gradient Magnet Design for Simultaneous Detection of Electrons and Positrons in the Intermediate MeV Range
- Nonlinear Inverse Compton Scattering from a Laser Wakefield Accelerator and Plasma Mirror