Abstract
Advances in integrated photonics open exciting opportunities for batch-fabricated optical sensors using high quality factor nanophotonic cavities to achieve ultra-high sensitivities and bandwidths. The sensitivity improves with higher optical power, however, localized absorption and heating within a micrometer-scale mode volume prominently distorts the cavity resonances and strongly couples the sensor response to thermal dynamics, limiting the sensitivity and hindering the measurement of broadband time-dependent signals. Here, we derive a frequency-dependent photonic sensor transfer function that accounts for thermo-optical dynamics and quantitatively describes the measured broadband optomechanical signal from an integrated photonic atomic-force-microscopy nanomechanical probe. Using this transfer function, the probe can be operated in the high optical power, strongly thermo-optically nonlinear regime, reaching a sensitivity of 0.4 fm/Hz, an improvement of relative to the best performance in the linear regime. Counterintuitively, we discover that higher transduction gain and sensitivity are obtained with lower quality factor optical modes for low signal frequencies. Not limited to optomechanical transducers, the derived transfer function is generally valid for describing small-signal dynamic response of a broad range of technologically important photonic sensors subject to the thermo-optical effect.
References in corpus (13)
- Resolved-sideband cooling and measurement of a micromechanical oscillator close to the quantum limit
- A hybrid on-chip opto-nanomechanical transducer for ultra-sensitive force measurements
- Cavity Optomechanical Magnetometer
- Temperature dependent refractive index of silicon and germanium
- Chasing the thermodynamical noise limit in whispering-gallery-mode resonators for ultrastable laser frequency stabilization
- Measuring nanomechanical motion with an imprecision far below the standard quantum limit
- On chip, high-sensitivity thermal sensor based on high-Q polydimethylsiloxane-coated microresonator
- Optomechanical transduction of an integrated silicon cantilever probe using a microdisk resonator
- Nanocavity optomechanical torque magnetometry and radiofrequency susceptometry
- Wide Stiffness Range Cavity Optomechanical Sensors for Atomic Force Microscopy
- Optical coupling to nanoscale optomechanical cavities for near quantum-limited motion transduction
- Accurate measurement of scattering and absorption loss in microphotonic devices
- Using thermo-optical nonlinearity to robustly separate absorption and radiation losses in nanophotonic resonators