BeyondPlanck VII. Bayesian estimation of gain and absolute calibration for CMB experiments
arXiv:2011.08082 · doi:10.1051/0004-6361/202244061
Abstract
We present a Bayesian calibration algorithm for CMB observations as implemented within the global end-to-end BeyondPlanck (BP) framework, and apply this to the Planck Low Frequency Instrument (LFI) data. Following the most recent Planck analysis, we decompose the full time-dependent gain into a sum of three orthogonal components: One absolute calibration term, common to all detectors; one time-independent term that can vary between detectors; and one time-dependent component that is allowed to vary between one-hour pointing periods. Each term is then sampled conditionally on all other parameters in the global signal model through Gibbs sampling. The absolute calibration is sampled using only the orbital dipole as a reference source, while the two relative gain components are sampled using the full sky signal, including the orbital and Solar CMB dipoles, CMB fluctuations, and foreground contributions. We discuss various aspects of the data that influence gain estimation, including the dipole/polarization quadrupole degeneracy and anomalous jumps in the instrumental gain. Comparing our solution to previous pipelines, we find good agreement in general, with relative deviations of -0.67% (-0.84%) for 30 GHz, 0.12% (-0.04%) for 44 GHz and -0.03% (-0.64%) for 70 GHz, compared to Planck DR4 (Planck 2018). The deviations we find are within expected error bounds, and we attribute them to differences in data usage and general approach between the pipelines. In particular, the BP calibration is performed globally, resulting in better inter-frequency consistency. Additionally, WMAP observations are used actively in the BP analysis, which breaks degeneracies in the Planck data set and results in better agreement with WMAP. Although our presentation and algorithm are currently oriented toward LFI processing, the procedure is fully generalizable to other experiments.
19 pages, 18 figures. All BeyondPlanck products and software will be released publicly at http://beyondplanck.science
References in corpus (24)
- Nine-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Final Maps and Results
- Five-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Data Processing, Sky Maps, and Basic Results
- Planck 2018 results. I. Overview and the cosmological legacy of Planck
- The Temperature of the Cosmic Microwave Background
- The Primordial Inflation Explorer (PIXIE): A Nulling Polarimeter for Cosmic Microwave Background Observations
- Detection of Polarization in the Cosmic Microwave Background using DASI
- Planck Early Results: The Planck mission
- Planck 2018 results. IV. Diffuse component separation
- Planck intermediate results. XLVI. Reduction of large-scale systematic effects in HFI polarization maps and estimation of the reionization optical depth
- Planck 2018 results. III. High Frequency Instrument data processing and frequency maps
- Planck intermediate results. LVII. Joint Planck LFI and HFI data processing
- Planck 2015 results. VIII. High Frequency Instrument data processing: Calibration and maps
- Planck 2013 results. XXVIII. The Planck Catalogue of Compact Sources
- Three-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Beam Profiles, Data Processing, Radiometer Characterization and Systematic Error Limits
- Planck 2013 results. VIII. HFI photometric calibration and mapmaking
- Planck 2018 results. II. Low Frequency Instrument data processing
- Planck 2013 results. II. Low Frequency Instrument data processing
- Planck 2015 results. V. LFI calibration
- SRoll2: an improved mapmaking approach to reduce large-scale systematic effects in the Planck High Frequency Instrument legacy maps
- BeyondPlanck I. Global Bayesian analysis of the Planck Low Frequency Instrument data
- From BeyondPlanck to Cosmoglobe: Preliminary -band analysis
- BeyondPlanck VI. Noise characterization and modelling
- BeyondPlanck X. Planck LFI frequency maps with sample-based error propagation
- BeyondPlanck IV. On end-to-end simulations in CMB analysis -- Bayesian versus frequentist statistics
Cited by in corpus (16)
- BeyondPlanck III. Commander3
- BeyondPlanck I. Global Bayesian analysis of the Planck Low Frequency Instrument data
- BeyondPlanck XIII. Intensity foreground sampling, degeneracies, and priors
- Tensor-to-scalar ratio forecasts for extended LiteBIRD frequency configurations
- BeyondPlanck XI. Bayesian CMB analysis with sample-based end-to-end error propagation
- Cosmoglobe DR1 results. I. Improved Wilkinson Microwave Anisotropy Probe maps through Bayesian end-to-end analysis
- BeyondPlanck XII. Cosmological parameter constraints with end-to-end error propagation
- From BeyondPlanck to Cosmoglobe: Preliminary -band analysis
- BeyondPlanck VI. Noise characterization and modelling
- BeyondPlanck XVI. Limits on Large-Scale Polarized Anomalous Microwave Emission from Planck LFI and WMAP
- BeyondPlanck X. Planck LFI frequency maps with sample-based error propagation
- Impact of half-wave plate systematics on the measurement of CMB -mode polarization
- BeyondPlanck VIII. Efficient Sidelobe Convolution and Correction through Spin Harmonics
- BeyondPlanck IV. On end-to-end simulations in CMB analysis -- Bayesian versus frequentist statistics
- Cosmoglobe DR1. III. First full-sky model of polarized synchrotron emission from all WMAP and Planck LFI data
- BeyondPlanck V. Minimal ADC Corrections for Planck LFI