Total-internal-reflection deflectometry for measuring small deflections of a fluid surface
arXiv:2009.00531 · doi:10.1007/s00348-021-03328-y
Abstract
We describe a method that uses total internal reflection at the water-air interface inside a large, transparent tank, to measure the interface's deflections. Using this configuration, we obtain an optical set-up where the liquid surface acts as a deformable mirror. The set-up is shown to be extremely sensitive to very small disturbances of the reflecting water surface, which are detected by means of visualising the reflections of a reference pattern. When the water surface is deformed, it reflects a distorted image of the reference pattern, similar to a synthetic Schlieren set-up. The distortions of the pattern are analysed using a suitable image correlation method. The displacement fields thus obtained correlate to the local spatial gradients of the water surface. The gradient fields are integrated in a least-squares sense to obtain a full instantaneous reconstruction of the water surface. This method is particularly useful when a solid object is placed just above water surface, whose presence makes the liquid surface otherwise optically inaccessible.
arXiv comment14 pages, 5 figures. Sample images and processing code in `ancillary files' directory
References in corpus (9)
- Controlled impact of a disk on a water surface: Cavity dynamics
- Real-time quantitative Schlieren imaging by fast Fourier demodulation of a checkered backdrop
- Excited Sessile Drops Dance Harmonically
- Splash wave and crown breakup after disc impact on a liquid surface
- Surface deformations and wave generation by wind blowing over a viscous liquid
- Air Entrapment and its effect on Pressure Impulses in the slamming of a Flat Disc on Water
- Air-cushioning effect and Kelvin-Helmholtz instability before the slamming of a disk on water
- Air flow in a collapsing cavity
- Compressible air flow through a collapsing liquid cavity