Suppression of Coriolis error in weak equivalence principle test using ^[85]Rb-^[87]Rb dual-species atom interferometer
arXiv:2005.11919 · doi:10.1088/1674-1056/ab969a
Abstract
Coriolis effect is an important error source in the weak equivalence principle (WEP) test using atom interferometer. In this paper, the problem of Coriolis error in WEP test is studied theoretically and experimentally. In theoretical simulation, Coriolis effect is analyzed by establishing an error model. The measurement errors of Eotvos coefficient (eta) in WEP test related to experimental parameters, such as horizontal-velocity difference and horizontal-position difference of atomic clouds, horizontal-position difference of detectors and rotation compensation of Raman laser's mirror are calculated. In experimental investigation, the position difference between Rb-85 and Rb-87 atomic clouds is reduced to 0.1 mm by optimizing the experimental parameters, an alternating detection method is used to suppress the error caused by detection position difference, thus the Coriolis error related to atomic clouds and detectors is eliminated to 1.1E-9. This Coriolis error is further corrected by compensating the rotation of Raman laser's mirror, and the total uncertainty of eta measurement related to Coriolis effect is reduced as 4.4E-11.
arXiv comment15 pages, 9 figures
References in corpus (20)
- Multi-axis inertial sensing with long-time point source atom interferometry
- 6-axis inertial sensor using cold-atom interferometry
- Quantum Test of the Universality of Free Fall
- Atomic Interferometer with Amplitude Gratings of Light and its Applications to Atom Based Tests of the Equivalence Principle
- Test of Equivalence Principle at Level by a Dual-species Double-diffraction Raman Atom Interferometer
- Test of Einstein Equivalence Principle for 0-spin and half-integer-spin atoms: Search for spin-gravity coupling effects
- Mobile quantum gravity sensor with unprecedented stability
- Gravity surveys using a mobile atom interferometer
- Precision measurement of gravity with cold atoms in an optical lattice and comparison with a classical gravimeter
- Quantum test of the equivalence principle for atoms in superpositions of internal energy eigenstates
- Dual Matter-Wave Inertial Sensors in Weightlessness
- Simultaneous Dual-Species Matter-Wave Accelerometer
- Compact cold atom gravimeter for field applications
- Influence of the Coriolis force in atom interferometry
- Test of the universality of free fall with atoms in different spin Orientations
- Test of the universality of free fall with atoms in different spin orientations
- Comparison between two mobile absolute gravimeters: optical versus atomic interferometers
- Calibration of atomic trajectories in a large-area dual-atom-interferometer gyroscope
- Effective velocity distribution in an atom gravimeter: effect of the convolution with the response of the detection
- Testing the Universality of Free Fall at level by Comparing the Atoms in Different Hyperfine States with Bragg Diffraction