In-situ gamma-ray background measurements for next generation CDEX experiment in the China Jinping Underground Laboratory
arXiv:2005.05498 · doi:10.1016/j.astropartphys.2021.102560
Abstract
In-situ -ray measurements were performed using a portable high purity germanium spectrometer in Hall-C at the second phase of the China Jinping Underground Laboratory (CJPL-II) to characterise the environmental radioactivity background below 3 MeV and provide ambient -ray background parameters for next generation of China Dark Matter Experiment (CDEX). The integral count rate of the spectrum was 46.8 cps in the energy range of 60 to 2700 keV. Detection efficiencies of the spectrometer corresponding to concrete walls and surrounding air were obtained from numerical calculation and Monte Carlo simulation, respectively. The radioactivity concentrations of the walls in the Hall-C were calculated to be Bq/kg for U, Bq/kg for Th, Bq/kg for K. Based on the measurement results, the expected background rates from these primordial radionuclides of future CDEX experiment were simulated in unit of counts per keV per ton per year (cpkty) for the energy ranges of 2 to 4 keV and around 2 MeV. The total background level from primordial radionuclides with decay products in secular equilibrium are and cpkty for energy ranges of 2 keV to 4 keV and around 2 MeV, respectively.
arXiv comment5 pages, 3 figures
References in corpus (17)
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- Muon-Induced Background Study for Underground Laboratories
- First Results from the Cryogenic Dark Matter Search in the Soudan Underground Lab
- Constraints on Spin-Independent Nucleus Scattering with sub-GeV Weakly Interacting Massive Particle Dark Matter from the CDEX-1B Experiment at the China Jin-Ping Laboratory
- Limits on Light Weakly Interacting Massive Particles from the First 102.8 kg day Data of the CDEX-10 Experiment
- The China Jinping Underground Laboratory and its Early Science
- Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China Jingping Underground Laboratory
- Measurement of Cosmic Ray Flux in China JinPing underground Laboratory
- Search for Light Weakly-Interacting-Massive-Particle Dark Matter by Annual Modulation Analysis with a Point-Contact Germanium Detector at the China Jinping Underground Laboratory
- Limits on light WIMPs with a 1 kg-scale germanium detector at 160 eVee physics threshold at the China Jinping Underground Laboratory
- Measurements of muon flux at 1070 metres vertical depth in the Boulby underground laboratory
- Direct Detection Constraints on Dark Photons with CDEX-10 Experiment at the China Jinping Underground Laboratory
- Muon Flux Measurements at the Davis Campus of the Sanford Underground Research Facility with the Majorana Demonstrator Veto System
- Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility
- CDEX dark matter experiment: Status and prospects
- Neutron background measurements at China Jinping underground laboratory with a Bonner Multi-sphere Spectrometer
- Results of direct dark matter detection with CDEX experiment at CJPL
Cited by in corpus (6)
- NvDEx-100 Conceptual Design Report
- Exploring New Physics with PandaX-4T Low Energy Electronic Recoil Data
- SAGE : A Monte Carlo Simulation Framework for Experiments with Germanium Detectors
- Projected WIMP sensitivity of the CDEX-50 dark matter experiment
- CENS Experiment Proposal at CSNS
- Study on cosmogenic activation in copper for rare event search experiments