NuSTAR low energy effective area correction due to thermal blanket tear
arXiv:2005.00569
Abstract
A rip in the MLI at the exit aperture of OMA, the NuSTAR optic aligned with detector focal plane module FPMA, has resulted in an increased photon flux through OMA that has manifested itself as a low energy excess. Overall, the MLI coverage has decreased by 10%, but there is an additional time-varying component, which occasionally causes the opening to increase by up to 20%. We address the problem with a calibration update, and in this paper, we describe the attributes of the problem, the implications it has on data analysis, and the solution.
The paper has been updated for the NuSTARDAS release v. 2.0.0 and CALDB version 20200813
Cited by in corpus (14)
- Insight-HXMT observations of jet-like corona in a black hole X-ray binary MAXI J1820+070
- Uncovering the geometry of the hot X-ray corona in the Seyfert galaxy NGC4151 with IXPE
- A New Spin on an Old Black Hole: NuSTAR Spectroscopy of EXO 1846-031
- NuSTAR monitoring of MAXI J1348-630: evidence of high density disc reflection
- Continuum, cyclotron line, and absorption variability in the high-mass X-ray binary Vela X-1
- Outflows and spectral evolution in the eclipsing AMXP SWIFT J1749.4-2807 with NICER, XMM-Newton and NuSTAR
- Distinct High Energy Cutoff Variation Patterns in Two Seyfert Galaxies
- Observing the onset of the accretion wake in Vela X-1
- The Inner Accretion Flow in the Resurgent Seyfert-1.2 AGN Mrk 817
- A New Transient Ultraluminous X-ray Source in NGC 7090
- Accreting on the edge: a luminosity-dependent cyclotron line in the Be/X-ray Binary 2S 1553-542 accompanied by accretion regimes transition
- Photospheric Radius Expansion and a double-peaked type-I X-ray burst from GRS 1741.9-2853
- The Spin and Orientation of the Black Hole in XTE J1908094
- 2021 Effective Area calibration of the Nuclear Spectroscopic Telescope ARray (NuSTAR)