Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
arXiv:2004.13895 · doi:10.1016/j.nima.2020.164382
Abstract
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~m were irradiated in steps of roughly 2 up to a fluence of . As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at .
References in corpus (5)
- Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
- Radiation Hardness of Thin Low Gain Avalanche Detectors
- Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector
- Gain and time resolution of 45 m thin Low Gain Avalanche Detectors before and after irradiation up to a fluence of n/cm
- Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector