paper

Development of gamma insensitive silicon carbide diagnostics to qualify intense thermal and epithermal neutron fields

arXiv:2004.08268 · doi:10.1088/1748-0221/15/06/C06021

Abstract

The e_LiBANS project aims at creating accelerator based compact neutron facilities for diverse interdisciplinary applications. After the successful setting up and characterization of a thermal neutron source based on a medical electron LINAC, a similar assembly for epithermal neutrons has been developed. The project is based on an Elekta 18 MV LINAC coupled with a photoconverter-moderator system which deploys the (γ,n) photonuclear reaction to convert a bremsstrahlung photon beam into a neutron field. This communication describes the development of novel diagnostics to qualify the thermal and epithermal neutron fields that have been produced. In particular, a proof of concept for the use of silicon carbide photodiodes as a thermal neutron rate detector is presented.

10 pages, 10 figures, accepted for publication to JINST on the 17th April 2020