Progress in the development of frequency domain multiplexing for the X-ray Integral Field Unit on board the Athena mission
arXiv:2003.11899 · doi:10.1007/s10909-020-02351-3
Abstract
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model (DM) with the single pixel AC bias (1.8 eV) and 9 pixel multiplexing (2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by non-fundamental issues related to FDM readout in our lab setup.
arXiv comment7 pages, 5 figures. Published on Journal of Low Temperature Physics (2020)
References in corpus (1)
Cited by in corpus (12)
- A Review of X-ray Microcalorimeters Based on Superconducting Transition Edge Sensors for Astrophysics and Particle Physics
- High Aspect Ratio Transition Edge Sensors for X-ray Spectrometry
- Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout
- Performance and uniformity of a kilo-pixel array of Ti/Au transition-edge sensor microcalorimeters
- Impact of the absorber coupling design for Transition Edge Sensor X-ray Calorimeters
- Frequency Shift Algorithm: Application to a Frequency-Domain Multiplexing Readout of X-ray Transition-Edge Sensor Microcalorimeters
- TiAu TES 3232 pixel array: uniformity, thermal crosstalk and performance at different X-ray energies
- Frequency Shift Algorithm: Design of a Baseband Phase Locked Loop for Frequency-Domain Multiplexing Readout of X-ray Transition-Edge Sensor Microcalorimeters
- Single pixel performance of a 3232 Ti/Au TES array with broadband X-ray spectra
- The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
- Demonstration of MHz frequency domain multiplexing readout of 37 transition edge sensors for high-resolution x-ray imaging spectrometers
- High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches