First results on the performance of the PADME electromagnetic calorimeter
arXiv:2002.11671 · doi:10.1088/1748-0221/15/05/C05008
Abstract
The PADME experiment, hosted at the Laboratori Nazionali di Frascati in Italy, is dedicated to the dark photon search. It looks for the reaction , where indicates the dark photon. The positrons beam that impinges on electrons, coming from an active diamond target, allows to scan masses up to . In this context, the segmented electromagnetic calorimeter plays a fundamental role, since it measures the final photon four-momentum. It consists of BGO crystals displaced in a cylindrical shape of radius with a central square hole of crystals side, to let Bremsstrahlung radiation pass, to limit the calorimeter trigger rate. Each crystal is read by a HZC XP1911 type B photomultipliers and their signal is digitised by means of a CAEN V1742 board, taking samples at . Here we report in detail the solutions adopted for the calorimeter together with the results obtained in tests performed on a small prototype and on single scintillating units.
10 pages, 9 figures