Optical characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019
arXiv:2002.05197 · doi:10.1007/s10909-020-02392-8
Abstract
The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale Cosmic Microwave Background (CMB) polarization from the South Pole in search of a primordial -mode signature. This -mode signal arises from primordial gravitational waves interacting with the CMB, and has amplitude parametrized by the tensor-to-scalar ratio . Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier Transform Spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.
arXiv comment8 pages, 3 figures. Accepted by the Journal of Low Temperature Physics (Proceedings of the 18th International Workshop on Low Temperature Detectors)
References in corpus (8)
- BICEP2 / Keck Array x: Constraints on Primordial Gravitational Waves using Planck, WMAP, and New BICEP2/Keck Observations through the 2015 Season
- Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
- BICEP2 III: Instrumental Systematics
- 2017 upgrade and performance of BICEP3: a 95GHz refracting telescope for degree-scale CMB polarization
- BICEP2 / Keck Array XI: Beam Characterization and Temperature-to-Polarization Leakage in the BK15 Dataset
- Microwave multiplexing on the Keck Array
- Design and performance of wide-band corrugated walls for the BICEP Array detector modules at 30/40 GHz
- Optical Characterization of the BICEP3 CMB Polarimeter at the South Pole
Cited by in corpus (7)
- Probing Lorentz-violating electrodynamics with CMB polarization
- Design and performance of the first BICEP Array receiver
- QUBIC VIII: Optical design and performance
- QUBIC V: Cryogenic system design and performance
- Cosmology Large Angular Scale Surveyor (CLASS): 90 GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance
- Total power horn-coupled 150 GHz LEKID array for space applications
- Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole