paper

Single-shot multi-keV X-ray absorption spectroscopy using an ultrashort laser wakefield accelerator source

arXiv:1907.10167 · doi:10.1103/PhysRevLett.123.254801

Abstract

Single-shot absorption measurements have been performed using the multi-keV X-rays generated by a laser wakefield accelerator. A 200 TW laser was used to drive a laser wakefield accelerator in a mode which produced broadband electron beams with a maximum energy above 1 GeV and a broad divergence of miliradians FWHM. Betatron oscillations of these electrons generated photons/eV in the 5 keV region, with a signal-to-noise ratio of approximately 300:1. This was sufficient to allow high-resolution XANES measurements at the K-edge of a titanium sample in a single shot. We demonstrate that this source is capable of single-shot, simultaneous measurements of both the electron and ion distributions in matter heated to eV temperatures by comparison with DFT simulations. The unique combination of a high-flux, large bandwidth, few femtosecond duration X-ray pulse synchronised to a high-power laser will enable key advances in the study of ultra-fast energetic processes such as electron-ion equilibration.

6 pages and 4 figures in main text, 3 pages and 4 figures in supplementary material