The shape of the Photon Transfer Curve of CCD sensors
arXiv:1905.08677 · doi:10.1051/0004-6361/201935508
Abstract
The Photon Transfer Curve (PTC) of a CCD depicts the variance of uniform images as a function of their average. It is now well established that the variance is not proportional to the average, as Poisson statistics would indicate, but rather flattens out at high flux. This "variance deficit", related to the brighter-fatter effect, feeds correlations between nearby pixels, that increase with flux, and decay with distance. We propose an analytical expression for the PTC shape, and for the dependence of correlations with intensity, and relate both to some more basic quantities related to the electrostatics of the sensor, that are commonly used to correct science images for the brighter-fatter effect. We derive electrostatic constraints from a large set of flat field images acquired with a CCD e2v 250, and eventually question the generally-admitted assumption that boundaries of CCD pixels shift by amounts proportional to the source charges. Our results show that the departure of flat field statistics from Poisson law is entirely compatible with charge redistribution during the drift in the sensor.
arXiv comment16 pages. Accepted for publication in A&A
References in corpus (11)
- Improved cosmological constraints from a joint analysis of the SDSS-II and SNLS supernova samples
- The first-year shear catalog of the Subaru Hyper Suprime-Cam SSP Survey
- The brighter-fatter effect and pixel correlations in CCD sensors
- Characterization and correction of charge-induced pixel shifts in DECam
- Evidence for self-interaction of charge distribution in charge-coupled devices
- Photometry of supernovae in an image series : methods and application to the Supernova Legacy Survey (SNLS)
- Exploring the brighter fatter effect with the Hyper Suprime-Cam
- Measurements and Simulations of the Brighter-Fatter Effect in CCD Sensors
- Precision Astronomy with Imperfect Fully Depleted CCDs -- An Introduction and a Suggested Lexicon
- The DICE calibration project: design, characterization, and first results
- Instrumental systematics and weak gravitational lensing
Cited by in corpus (10)
- Dark Energy Survey Year 3 Results: Weak Lensing Shape Catalogue
- Brighter-fatter effect in near-infrared detectors -- I. Theory of flat auto-correlations
- PlatoSim: An end-to-end PLATO camera simulator for modelling high-precision space-based photometry
- Brighter-fatter effect in near-infrared detectors -- III. Fourier-domain treatment of flat field correlations and application to WFIRST
- Quantum yield and charge diffusion in the Nancy Grace Roman Space Telescope infrared detectors
- Sensor Distortion Effects in Photon Monte Carlo Simulations
- StarDICE I: sensor calibration bench and absolute photometric calibration of a Sony IMX411 sensor
- Correction of the brighter-fatter effect on the CCDs of Hyper Suprime-Cam
- Spot-Based Measurement of the Brighter-Fatter Effect on a Roman Space Telescope H4RG Detector and Comparison with Flat-Field Data
- Linearity and correction of the BF effect in LSST sensors