Twente Mass and Heat Transfer Water Tunnel: Temperature controlled turbulent multiphase channel flow with heat and mass transfer
arXiv:1902.05871 · doi:10.1063/1.5092967
Abstract
A new vertical water tunnel with global temperature control and the possibility for bubble and local heat & mass injection has been designed and constructed. The new facility offers the possibility to accurately study heat and mass transfer in turbulent multiphase flow (gas volume fraction up to ) with a Reynolds-number range from to in the case of water at room temperature. The tunnel is made of high-grade stainless steel permitting the use of salt solutions in excess of 15 mass fraction. The tunnel has a volume of 300 liters. The tunnel has three interchangeable measurement sections of m height but with different cross sections (, , ). The glass vertical measurement sections allow for optical access to the flow, enabling techniques such as laser Doppler anemometry, particle image velocimetry, particle tracking velocimetry, and laser-induced fluorescent imaging. Local sensors can be introduced from the top and can be traversed using a built-in traverse system, allowing for e.g. local temperature, hot-wire, or local phase measurements. Combined with simultaneous velocity measurements, the local heat flux in single phase and two phase turbulent flows can thus be studied quantitatvely and precisely.