Tests of cryogenic Fabry-Perot cavity with mirrors on different substrates
arXiv:1902.03452 · doi:10.3390/app9020230
Abstract
Experiments were performed with Fabry-Perot optical resonators in vacuum at low temperatures. Mirrors were applied on substrates of various optical materials. The infrared laser with a wavelength of 1.064 microns was used. The pump power at the maximum could reach 450 mW. The evolution of the optical properties of the FP cavity was traced in the temperature range (300 - 10)K. The main parameters measured were the integral characteristics of the FP resonances: sharpness (finesse) and contrast of interference. Three types of substrates were tested: a sitall -- the optical glass with ultra low thermal expansion (ULE), sapphire and calcium fluoride. During cooling, the degradation of the integral characteristics of the FP cavity was observed for the sitall mirrors due to the loss of the properties of (ULE), for sapphire mirrors due to the birefringence effect. The satisfactory constancy of the integral characteristics of the FP resonator on calcium fluoride was demonstrated in the entire temperature range studied 1
arXiv comment12 pages, 6 figures
References in corpus (11)
- The Confrontation between General Relativity and Experiment
- Interferometer design of the KAGRA gravitational wave detector
- Detector configuration of KAGRA - the Japanese cryogenic gravitational-wave detector
- Gravitational Radiation Detection with Laser Interferometry
- Titania-doped tantala/silica coatings for gravitational-wave detection
- Mechanical Loss in Tantala/Silica Dielectric Mirror Coatings
- Beyond the Second Generation of Laser-Interferometric Gravitational Wave Observatories
- Mirror thermal noise in laser interferometer gravitational wave detectors operating at room and cryogenic temperature
- Thermal-noise-limited underground interferometer CLIO
- Current status of the CLIO project
- Molecular adsorbed layer formation on cooled mirrors and its impacts on cryogenic gravitational wave telescopes