paper

Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam

arXiv:1812.11426 · doi:10.1140/epjc/s10052-019-7077-9

Abstract

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.

16 pages, 28 figures, Published in EPJC. Please note: Fig 16 in the published version us incorrect. The correct one appears in this replaced version