Experimental investigation of the low molecular weight fluoropolymer for the ultracold neutrons storage
arXiv:1811.01859 · doi:10.1134/S1547477118050072
Abstract
The experimental setup for examining the low-molecular-weight fluoropolymer CF(CF-O-CF-O-(CFCF, which is a promising coating material for the walls of storage chambers for ultracold neutrons, is described. The results are detailed. The measurement data are interpreted in the model of a multilayer complex quantum-mechanical potential of the chamber walls.
Corrected version of the paper published in Phys. of Part. and Nucl Lett., 15 (No.5) (2018) 541
References in corpus (6)
- Improved Determination of the Neutron Lifetime
- Neutron -- Mirror Neutron Oscillation: How Fast Might It Be?
- Neutron lifetime measurements using gravitationally trapped ultracold neutrons
- More about neutron - mirror neutron oscillation
- Search for passing-through-walls neutrons constrains hidden braneworlds
- Options for the Neutron Lifetime Measurements in Traps