High-speed standard magneto-rotational instability
arXiv:1811.00001 · doi:10.1017/jfm.2019.67
Abstract
The large Reynolds number asymptotic approximation of the neutral curve of Taylor-Couette flow subject to axial uniform magnetic field is analysed. The flow has been extensively studied since early 90's as the magneto-rotational instability (MRI) occurring in the flow could possibly explain the origin of the instability observed in certain astrophysical objects. Elsewhere the ideal approximation has been used to study high-speed flows, whilst it sometimes produces paradoxical results. For example, ideal flows must be completely stabilised for strong enough applied magnetic field, but on the other hand the vanishing magnetic Prandtl number limit of the stability should be purely hydrodynamic so instability must occur when Rayleigh's stability condition is violated. The first our discovery is that this apparent contradiction can be resolved by showing the abrupt appearance of the hydrodynamic instability at certain critical value of magnetic Prandtl number, which can be found by asymptotically large Reynolds number limit but with long enough wavelength to retain some diffusive effects. The second our finding concerns so-called Velikhov-Chandrasekhar paradox, namely the mismatch of the zero external magnetic field limit of the Velikhov-Chandrasekhar stability criterion and Rayleigh's stability criterion. We show for fully wide gap cases that the high Reynolds number asymptotic analysis of the MRI naturally yields the simple stability condition that describes smooth transition from Rayleigh to Velikhov-Chandrasekhar stability criteria with increasing Lundquist number.
arXiv comment29 pages, 11 figures
References in corpus (14)
- Magnetorotational Instability in a Rotating Liquid Metal Annulus
- Experimental evidence for magnetorotational instability in a helical magnetic field
- New type of magneto-rotational instability in cylindrical Taylor-Couette flow
- Helical Magnetorotational Instability in Magnetized Taylor-Couette Flow
- Magnetorotational instability of dissipative Couette flow
- Experiments on the magnetorotational instability in helical magnetic fields
- The linear MHD Taylor-Couette instability for liquid sodium
- The traveling wave MRI in cylindrical Taylor-Couette flow: comparing wavelengths and speeds in theory and experiment
- Stability and instability of hydromagnetic Taylor-Couette flows
- Magnetic instability in a sheared azimuthal flow
- Inviscid helical magnetorotational instability in cylindrical Taylor-Couette flow
- Paradoxes of magnetorotational instability and their geometrical resolution
- Magnetorotational instability in Taylor-Couette flows between cylinders with finite electrical conductivity
- Paradoxical transitions to instabilities in hydromagnetic Couette-Taylor flows