Overcoming inefficient detection in sub-shot-noise absorption measurement and imaging
arXiv:1810.08115 · doi:10.1364/OE.27.007868
Abstract
Photon-number squeezing and correlations enable measurement of absorption with an accuracy exceeding that of the shot-noise limit. However, sub-shot noise imaging and sensing based on these methods require high detection efficiency, which can be a serious obstacle if measurements are carried out in "difficult" spectral ranges. We show that this problem can be overcome through the phase-sensitive amplification before detection. Here we propose an experimental scheme of sub-shot-noise imaging with tolerance to detection losses.
arXiv comment24 pages, 9 figures, single column
References in corpus (23)
- Quantum-enhanced measurements: beating the standard quantum limit
- Detection of 15 dB Squeezed States of Light and their Application for the Absolute Calibration of Photoelectric Quantum Efficiency
- Experimental realization of sub-shot-noise quantum imaging
- Quantum Illumination with Gaussian States
- Quantum limits in optical interferometry
- Microwave Quantum Illumination
- Quantum Illumination at the Microwave Wavelengths
- Experimental realisation of quantum illumination
- Optimal quantum estimation of loss in bosonic channels
- Detection of sub-shot-noise spatial correlation in high-gain parametric down-conversion
- Quantum state magnification
- Realisation of the first sub shot noise wide field microscope
- Optimal estimation of losses at the ultimate quantum limit with non-Gaussian states
- Detection loss tolerant supersensitive phase measurement with an SU(1,1) interferometer
- Measurement of sub-shot-noise spatial correlations without subtraction of background
- Two-Color Bright Squeezed Vacuum
- High-sensitivity imaging with multi-mode twin beams
- Gaussian state interferometry with passive and active elements
- Quantum-enhanced absorption spectroscopy
- Improving the phase super-sensitivity of squeezing-assisted interferometers by squeeze factor unbalancing
- Unbiased estimation of an optical loss at the ultimate quantum limit with twin-beams
- Heralded Source of Bright Multi-mode Mesoscopic Sub-Poissonian Light
- Quantum tomography enhanced through parametric amplification
Cited by in corpus (14)
- Quantum imaging of biological organisms through spatial and polarization entanglement
- Wide-field SU(1,1) interferometer
- Overcoming detection loss and noise in squeezing-based optical sensing
- Quantum Advantage with Seeded Squeezed Light for Absorption Measurement
- Quantum differential ghost microscopy
- Improving resolution-sensitivity trade off in sub-shot noise imaging
- Mitigating quantum decoherence in force sensors by internal squeezing
- Quantum Enhanced Imaging of Non-Uniform Refractive Profiles
- A phase-sensitive optomechanical amplifier for quantum noise reduction in laser interferometers
- Classical and Quantum Frequency Combs for Satellite-based Clock Synchronization
- Fundamental sensitivity limit of lossy cavity-enhanced interferometers with external and internal squeezing
- Amplified Squeezed States: Analyzing Loss and Phase Noise
- Multimode optical parametric amplification in the phase-sensitive regime
- Weak Thermal State Quadrature-Noise Shadow Imaging