A Method of Alignment of the Plastic Scintillator Detector of DAMPE
arXiv:1808.05720 · doi:10.1088/1674-4527/19/6/82
Abstract
The Plastic Scintillator Detector (PSD) of the DArk Matter Particle Explorer (DAMPE) is designed to measure cosmic ray charge (Z) and to act as a veto detector for gamma-ray identification. In order to fully exploit the charge identification potential of the PSD and to enhance its capability to identify the gamma ray events, we develop a PSD detector alignment method. The path length of a given track in the volume of a PSD bar is derived taking into account the shift and rotation alignment corrections. By examining energy spectra of corner-passing events and fully contained events, position shifts and rotations of all PSD bars are obtained, and found to be on average about 1mm and 0.0015 radian respectively. To validate the alignment method, we introduce the artificial shifts and rotations of PSD bars in the detector simulation. These shift and rotation parameters can be recovered successfully by the alignment procedure. As a result of the PSD alignment procedure, the charge resolution of the PSD is improved from to depending on the nuclei.
arXiv comment11 pages,9 figures, submitted
References in corpus (7)
- Direct detection of a break in the teraelectronvolt cosmic-ray spectrum of electrons and positrons
- The DArk Matter Particle Explorer mission
- The Plastic Scintillator Detector at DAMPE
- The on-orbit calibration of DArk Matter Particle Explorer
- Charge Measurement of Cosmic Ray Nuclei with the Plastic Scintillator Detector of DAMPE
- Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
- An algorithm to resolve γ-rays from charged cosmic rays with DAMPE
Cited by in corpus (13)
- Measurement of the cosmic-ray proton spectrum from 40 GeV to 100 TeV with the DAMPE satellite
- Measurement of the cosmic ray helium energy spectrum from 70 GeV to 80 TeV with the DAMPE space mission
- Observations of Forbush Decreases of cosmic ray electrons and positrons with the Dark Matter Particle Explorer
- A deep learning method for the trajectory reconstruction of cosmic rays with the DAMPE mission
- Measurement of the cosmic p+He energy spectrum from 50 GeV to 0.5 PeV with the DAMPE space mission
- Correction Method for the Readout Saturation of the DAMPE Calorimeter
- Search for relativistic fractionally charged particles in space
- Boresight Alignment of DArk Matter Particle Explorer
- Study of the Global Alignment for the DAMPE Detector
- PSF Calibration of DAMPE for gamma-ray Observations
- The calibrations of DAMPE -ray effective area
- Energy correction based on fluorescence attenuation of DAMPE
- Investigation of hadronic cross sections of cosmic ray carbon and oxygen on BGO from 200 GeV to 10 TeV energy at the DAMPE experiment