Optomechanical non-contact measurement of microparticle compressibility in liquids
arXiv:1801.01163 · doi:10.1364/OE.26.031908
Abstract
High-throughput label-free measurements of the optical and mechanical properties of single microparticles play an important role in biological research, drug development, and related large population assays. Mechanical detection techniques that rely on the density contrast of a particle with respect to its environment are blind to neutrally bouyant particles. However, neutrally buoyant particles may still have a high compressibility contrast with respect to their environment, opening a window to detection. Here we present a label-free high-throughput approach for measuring the compressibility (bulk modulus) of freely flowing microparticles by means of resonant measurements in an opto-mechano-fluidic resonator.
arXiv comment4 pages of main text, with 4 figures
References in corpus (8)
- Cavity optomechanical transduction sensing of single molecules
- Brillouin cavity optomechanics with microfluidic devices
- High frequency nano-optomechanical disk resonators in liquids
- Cavity optomechanics on a microfluidic resonator with water and viscous liquids
- Nanocavity optomechanical torque magnetometry and radiofrequency susceptometry
- Opto-Mechano-Fluidic Viscometer
- Magnetic Actuation and Feedback Cooling of a Cavity Optomechanical Torque Sensor
- Imaging of acoustic pressure modes in opto-mechano-fluidic resonators with a single particle probe