Linear-Array Photoacoustic Imaging Using Minimum Variance-Based Delay Multiply and Sum Adaptive Beamforming Algorithm
arXiv:1709.07965 · doi:10.1117/1.JBO.23.2.026002
Abstract
In Photoacoustic imaging (PA), Delay-and-Sum (DAS) beamformer is a common beamforming algorithm having a simple implementation. However, it results in a poor resolution and high sidelobes. To address these challenges, a new algorithm namely Delay-Multiply-and-Sum (DMAS) was introduced having lower sidelobes compared to DAS. To improve the resolution of DMAS, a novel beamformer is introduced using Minimum Variance (MV) adaptive beamforming combined with DMAS, so-called Minimum Variance-Based DMAS (MVB-DMAS). It is shown that expanding the DMAS equation results in multiple terms representing a DAS algebra. It is proposed to use the MV adaptive beamformer instead of the existing DAS. MVB-DMAS is evaluated numerically and experimentally. In particular, at the depth of 45 mm MVB-DMAS results in about 31 dB, 18 dB and 8 dB sidelobes reduction compared to DAS, MV and DMAS, respectively. The quantitative results of the simulations show that MVB-DMAS leads to improvement in full-width-half-maximum about 96 %, 94 % and 45 % and signal-to-noise ratio about 89 %, 15 % and 35 % compared to DAS, DMAS, MV, respectively. In particular, at the depth of 33 mm of the experimental images, MVB-DMAS results in about 20 dB sidelobes reduction in comparison with other beamformers.
This is the final version of this paper, which is accepted in the "Journal of Biomedical Optics". Compared to previous versions, this version contains more experiments and evaluation
References in corpus (9)
- Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging
- Enhanced Linear-array Photoacoustic Beamforming using Modified Coherence Factor
- Double Stage Delay Multiply and Sum Beamforming Algorithm Applied to Ultrasound Medical Imaging
- A constrained variable projection reconstruction method for photoacoustic computed tomography without accurate knowledge of transducer responses
- Image Enhancement and Noise Reduction Using Modified Delay-Multiply-and-Sum Beamformer: Application to Medical Photoacoustic Imaging
- Eigenspace-Based Minimum Variance Adaptive Beamformer Combined with Delay Multiply and Sum: Experimental Study
- Medical Photoacoustic Beamforming Using Minimum Variance-Based Delay Multiply and Sum
- Image Improvement in Linear-Array Photoacoustic Imaging using High Resolution Coherence Factor Weighting Technique
- Photoacoustic Imaging using Combination of Eigenspace-Based Minimum Variance and Delay-Multiply-and-Sum Beamformers: Simulation Study
Cited by in corpus (14)
- Enhanced Linear-array Photoacoustic Beamforming using Modified Coherence Factor
- Double Stage Delay Multiply and Sum Beamforming Algorithm Applied to Ultrasound Medical Imaging
- Eigenspace-Based Minimum Variance Combined with Delay Multiply and Sum Beamformer: Application to Linear-Array Photoacoustic Imaging
- Photoacoustic Image Formation Based on Sparse Regularization of Minimum Variance Beamformer
- An Efficient Nonlinear Beamformer Based on P^{th} Root of Detected Signals for Linear-Array Photoacoustic Tomography: Application to Sentinel Lymph Node Imaging
- Eigenspace-Based Minimum Variance Adaptive Beamformer Combined with Delay Multiply and Sum: Experimental Study
- Model-Based Photoacoustic Image Reconstruction using Compressed Sensing and Smoothed L0 Norm
- Higher-order correlation based real-time beamforming in photoacoustic imaging
- Effects of Important Parameters Variations on Computing Eigenspace-Based Minimum Variance Weights for Ultrasound Tissue Harmonic Imaging
- Technical Considerations when using Verasonics Research Ultrasound Platform for Developing a Photoacoustic Imaging System
- Double Minimum Variance Beamforming Method to Enhance Photoacoustic Imaging
- Three-Dimensional Photoacoustic Tomography using Delay Multiply and Sum Beamforming Algorithm
- Complementary Capabilities of Photoacoustic Imaging to Existing Optical Ocular Imaging Techniques
- An Image Registration Based Technique for Noninvasive Vascular Elastography