Observation of second-order temporal interference with thermal light: Interference beyond the coherence time
arXiv:1706.00170 · doi:10.1103/PhysRevLett.119.263603
Abstract
We report observation of a counter-intuitive phenomenon in multi-path correlation interferometry with thermal light. The intensity correlation between the outputs of two unbalanced Mach-Zehnder interferometers (UMZI) with two classically correlated beams of thermal light at the input exhibits genuine second-order interference with the visibility of . Surprisingly, the second-order interference does not degrade at all no matter how much the path length difference in each UMZI is increased beyond the coherence length of the thermal light. Moreover, the second-order interference is dependent on the difference of the UMZI phases. These results differ substantially from those of the entangled-photon Franson interferometer which exhibits two-photon interference dependent on the sum of the UMZI phases and the interference vanishes as the path length difference in each UMZI exceeds the coherence length of the pump laser. Our work offers deeper insight into the interplay between interference and coherence in multi-photon interferometry.
accepted for publication in Physical Review Letters
References in corpus (14)
- Experimental evidence of high-resolution ghost imaging and ghost diffraction with classical thermal light
- Camparison of the Hanbury Brown-Twiss effect for bosons and fermions
- Two-photon interference with thermal light
- Multiboson Correlation Interferometry with arbitrary single-photon pure states
- High-visibility multi-photon interference of Hanbury Brown - Twiss type for classical light
- Non-monotonic quantum to classical transition in multiparticle interference
- Quantum and classical correlations of intense beams of light via joint photodetection
- Observation of detection-dependent multi-photon coherence times
- Storage and Retrieval of Thermal Light in Warm Atomic Vapor
- Multi-Boson Correlation Sampling with Multi-mode Thermal Sources
- Weak value measurement with an incoherent measuring device
- Multipath Correlation Interference and Controlled-NOT Gate Simulation with a Thermal Source
- Characterization of two distant double-slits by chaotic light second-order interference
- Spatial interference between pairs of disjoint optical paths with a single chaotic source
Cited by in corpus (11)
- Intensity interferometry for holography with quantum and classical light
- Heralded single-pixel imaging with high loss-resistance and noise-robustness
- Photon statistics of quantum light on scattering from rotating ground glass
- General considerations in unbalanced fourth-order interference
- Collective effects in the photon statistics of thermal atomic ensembles
- Distance sensing emerging from second-order interference of thermal light
- Phase Dependent Hanbury-Brown and Twiss effect
- Noise-robust single-pixel imaging in photon counting regime with a pulsed source
- The physics of thermal light second-order interference beyond coherence
- Optical interference by amplitude measurement
- Momentum-resolved two photon interference of weak coherent states