Directional dark matter detection sensitivity of a two-phase liquid argon detector
arXiv:1704.03741 · doi:10.1088/1475-7516/2019/01/014
Abstract
We examine the sensitivity of a large scale two-phase liquid argon detector to the directionality of the dark matter signal. This study was performed under the assumption that, above 50 keV of recoil energy, one can determine (with some resolution) the direction of the recoil nucleus without head-tail discrimination, as suggested by past studies that proposed to exploit the dependence of columnar recombination on the angle between the recoil nucleus direction and the electric field. In this paper we study the differential interaction recoil rate as a function of the recoil direction angle with respect to the zenith for a detector located at the Laboratori Nazionali del Gran Sasso and we determine its diurnal and seasonal modulation. Using a likelihood-ratio based approach we show that, with the angular information alone, 100 events are enough to reject the isotropic hypothesis at three standard deviation level. For an exposure of 100 tonne years this would correspond to a spin independent WIMP-nucleon cross section of about 10^-46 cm^2 at 200 GeV WIMP mass. The results presented in this paper provide strong motivation for the experimental determination of directional recoil effects in two-phase liquid argon detectors.
arXiv comment16 pages, 14 figures. This new version matches the published version
References in corpus (29)
- Planck 2015 results. XIII. Cosmological parameters
- Particle Dark Matter: Evidence, Candidates and Constraints
- Asymptotic formulae for likelihood-based tests of new physics
- A direct empirical proof of the existence of dark matter
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Results from a search for dark matter in the complete LUX exposure
- First results from DAMA/LIBRA and the combined results with DAMA/NaI
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- First Dark Matter Search Results from the XENON1T Experiment
- DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
- The Dark Matter Halo of the Milky Way, AD 2013
- Annual Modulation of Dark Matter: A Review
- A review of the discovery reach of directional Dark Matter detection
- Kinematic Disturbances in Optical Rotation Curves among 89 Virgo Disk Galaxies
- Scale-dependent non-Gaussianity probes inflationary physics
- The Dark Matter at the End of the Galaxy
- Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon
- Recoil momentum spectrum in directional dark matter detectors
- Readout technologies for directional WIMP Dark Matter detection
- Angular Signatures for Galactic Halo WIMP Scattering in Direct Detectors: Prospects and Challenges
- Assessing Astrophysical Uncertainties in Direct Detection with Galaxy Simulations
- Empirical Determination of Dark Matter Velocities using Metal-Poor Stars
- Directional recoil rates for WIMP direct detection
- Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field
- The Phase of the Annual Modulation as a Tool for Determining the WIMP Mass
- Estimating CDM Particle Trajectories in the Mildly Non-Linear Regime of Structure Formation. Implications for the Density Field in Real and Redshift Space
- Gauging the dark matter fraction in a S0 galaxy at z=0.47 through gravitational lensing from deep HST/ACS imaging
- Observation of annual modulation induced by rays from (, ) reactions at the Soudan Underground Laboratory
- Exclusion, Discovery and Identification of Dark Matter with Directional Detection
Cited by in corpus (7)
- Can we overcome the neutrino floor at high masses?
- Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter
- Direct Detection of Dark Matter -- APPEC Committee Report
- Directional detection of dark matter with diamond
- Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber
- The role of small scale experiments in the direct detection of dark matter
- Performance of the ReD TPC, a novel double-phase LAr detector with Silicon Photomultiplier Readout