First test of a high voltage feedthrough for liquid Argon TPCs connected to a 300 kV power supply
arXiv:1611.02085 · doi:10.1088/1748-0221/12/03/P03021
Abstract
Voltages above a hundred kilo-volt will be required to generate the drift field of future very large liquid Argon Time Projection Chambers. The most delicate component is the feedthrough whose role is to safely deliver the very high voltage to the cathode through the thick insulating walls of the cryostat without compromising the purity of the argon inside. This requires a feedthrough that is typically meters long and carefully designed to be vacuum tight and have small heat input. Furthermore, all materials should be carefully chosen to allow operation in cryogenic conditions. In addition, electric fields in liquid argon should be kept below a threshold to reduce risks of discharges. The combination of all above requirements represents significant challenges from the design and manufacturing perspective. In this paper, we report on the successful operation of a feedthrough satisfying all the above requirements. The details of the feedthrough design and its manufacturing steps are provided. Very high voltages up to unprecedented voltages of -300 kV could be applied during long periods repeatedly. A source of instability was observed, which was specific to the setup configuration which was used for the test and not due to the feedthrough itself.
arXiv comment13 pages, 9 figures
References in corpus (6)
- First operation of a double phase LAr Large Electron Multiplier Time Projection Chamber with a two-dimensional projective readout anode
- Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: comparison of single and double phase operation
- Performance study of the effective gain of the double phase liquid Argon LEM Time Projection Chamber
- Long-term operation of a double phase LAr LEM Time Projection Chamber with a simplified anode and extraction-grid design
- Experimental study of electric breakdowns in liquid argon at centimeter scale
- First operation and performance of a 200 lt double phase LAr LEM-TPC with a 40x76 cm^2 readout
Cited by in corpus (9)
- Gaseous and dual-phase time projection chambers for imaging rare processes
- A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
- Dielectric Strength of Noble and Quenched Gases for High Pressure Time Projection Chambers
- High Voltage Insulation and Gas Absorption of Polymers in High Pressure Argon and Xenon Gases
- Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
- ALETHEIA: Hunting for Low-mass Dark Matter with Liquid Helium TPCs
- Charge and Light Production in the Charge Readout System of a Dual Phase LAr TPC
- Cavallo's Multiplier for in situ Generation of High Voltage
- A plastic feedthrough suitable for high-voltage DC femtosecond electron diffractometers