Dual atomic interferometer with a tunable point of minimum magnetic sensitivity
arXiv:1610.06271 · doi:10.1103/PhysRevA.94.033634
Abstract
Atomic interferometers are often affected by magnetic field fluctuations. Using the clock transition at zero magnetic field minimizes the effect of these fluctuations. There is another transition in rubidium that minimizes the magnetic sensitivity at 3.2 G.We combine the previous two transitions to obtain minimum magnetic sensitivity at a tunable magnetic field between 2.2 and 3.2 G. The two interferometers evolve independently from each other and we control the magnetic sensitivity by changing the population in both transitions with a microwave pulse.
7 pages,7 figures
References in corpus (9)
- An Improved Experimental Limit on the Electric Dipole Moment of the Neutron
- Precision Measurement of the Newtonian Gravitational Constant Using Cold Atoms
- Quantum Information Processing in Optical Lattices and Magnetic Microtraps
- Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute
- Experimental observation of magic-wavelength behavior in optical lattice-trapped Rb
- Stability enhancement by joint phase measurements in a single cold atomic fountain
- Magic radio-frequency dressing of nuclear spins in high-accuracy optical clocks
- Multiple Isotope Magneto Optical Trap from a single diode laser
- Velocity selector with a microwave magnetic dipole transition