An approach to directly probe simultaneity
arXiv:1608.08516 · doi:10.1142/S0217732316501571
Abstract
The theory of special relativity derives from the Lorentz transformation. The Lorentz transformation implies differential simultaneity and light speed isotropy. Experiments to probe differential simultaneity should be able to distinguish the Lorentz transformation from a kinematically-similar alternate transformation that predicts absolute simultaneity, the absolute Lorentz transformation. Here, we describe how published optical tests of light speed isotropy/anisotropy cannot distinguish between the two transformations. We show that the shared equations of the two transformations, from the perspective of the "stationary" observer, are sufficient to predict null results in optical resonator experiments and in tests of frequency changes in one-way light paths. In an influential 1910 exposition on differential simultaneity, Comstock described how a "stationary" observer would observe different clock readings for spatially-separated "moving" clocks. The difference in clock readings is an integral aspect of differential simultaneity. We derive the equation for the difference in clock readings and show that it is equivalent to the Sagnac correction that describes light speed anisotropies in satellite communications. We describe an experimental strategy that can measure the differences in spatially-separated clock times to allow a direct probe of the nature of simultaneity.
19 pages, 4 figures. Published in Mod. Phys. Lett. A
References in corpus (17)
- An Optical Lattice Clock with Accuracy and Stability at the Level
- An atomic clock with instability
- Modern Michelson-Morley experiment using cryogenic optical resonators
- Rotating optical cavity experiment testing Lorentz invariance at the 10^{-17} level
- Tests of relativity using a microwave resonator
- Relativity tests by complementary rotating Michelson-Morley experiments
- Test of constancy of speed of light with rotating cryogenic optical resonators
- Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators
- Test of the isotropy of the speed of light using a continuously rotating optical resonator
- Improved Test of Lorentz Invariance in Electrodynamics
- Student understanding of time in special relativity: simultaneity and reference frames
- Improved test of Lorentz Invariance in Electrodynamics using Rotating Cryogenic Sapphire Oscillators
- Whispering Gallery Resonators and Tests of Lorentz Invariance
- Limits on light-speed anisotropies from Compton scattering of high-energy electrons
- Synchronization Gauges and the Principles of Special Relativity
- Probing the Light Speed Anisotropy with respect to the Cosmic Microwave Background Radiation Dipole
- A Review of One-Way and Two-Way Experiments to Test the Isotropy of the Speed of Light