In-orbit Performance of UVIT on ASTROSAT
arXiv:1608.01073 · doi:10.1117/12.2235271
Abstract
We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 . The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 - 1.7 in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15\% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.
arXiv comment10 pages, To appear in SPIE conference proceedings, SPIE conference paper, 2016
References in corpus (1)
Cited by in corpus (20)
- In-orbit Calibrations of the Ultra-Violet Imaging Telescope
- In-orbit Performance of UVIT and First Results
- UVIT Open Cluster Study. I. Detection of a White Dwarf Companion to a Blue Straggler in M67: Evidence of Formation through Mass Transfer
- Detection of a White Dwarf companion to a Blue Straggler Star in the outskirts of globular cluster NGC 5466 with the Ultraviolet Imaging Telescope (UVIT)
- The World Space Observatory Ultraviolet (WSO-UV), as a bridge to future UV astronomy
- The Horizontal Branch population of NGC 1851 as revealed by the Ultra-violet Imaging Telescope (UVIT)
- Investigating the In-Flight Performance of the UVIT Payload on ASTROSAT
- GlobULeS-IV. UVIT/AstroSat detection of extremely low mass white dwarf companions to blue straggler stars in NGC 362
- Peculiarities in the horizontal branch stars of globular cluster NGC 1851: Discovery of a Blue straggler companion to an EHB star
- UVIT-HST-GAIA view of NGC 288: A census of hot stellar population and their properties from UV
- UVIT Study of the MAgellanic Clouds (U-SMAC) II. A Far-UV catalog of the Small Magellanic Cloud: Morphology and Kinematics of young stellar population
- UV spectroscopy confirms SU Lyn to be a symbiotic star
- GlobULeS-V. UVIT/AstroSat studies of stellar populations in NGC 362: Detection of Blue Lurkers in a Globular Cluster
- AstroSat - a multi-wavelength astronomy satellite
- Ultraviolet Imaging Telescope (UVIT) observation of the Galactic Globular Cluster NGC 7492
- Detection of Faint Sources by the UltraViolet Imaging Telescope Onboard AstroSat Using Poisson Distribution of Background
- Study of UV bright stellar populations in the globular cluster NGC 1261 using AstroSat
- Exploring the archives: A search for novae in UVIT snapshots of M31
- UVIT-HST-Gaia-VISTA study of KRON 3 in the Small Magellanic Cloud: A cluster with an extended red clump in UV
- Study of dynamical status of the globular cluster NGC 1851 using Ultraviolet Imaging Telescope