Temperature coefficients of crystalline-quartz elastic constants over the cryogenic range [4 K, 15 K]
arXiv:1607.04584 · doi:10.1063/1.4971335
Abstract
This paper brings out results of a measurement campaign aiming to determine the temperature coefficients of synthetic quartz elastic constants at liquid helium temperature. The method is based on the relationship between the resonance frequencies of a quartz acoustic cavity and the elastic constants of the material. The temperature coefficients of the elastic constants are extracted from experimental frequency-temperature data collected from a set of resonators of various cut angles, because of the anisotropy of quartz, measured on the very useful cryogenic range [4 K - 15 K]. The knowledge of these temperature coefficients would allow to further design either quartz temperature sensors or conversely frequency-temperature compensated quartz cuts. With extremely low losses, lower than for the best ones, key applications of such devices are ultra-low loss mechanical systems used in many research areas including frequency control and fundamental measurements. The Eulerian formalism is used in this study to identify the temperature coefficients.
arXiv comment6 pages,4 figures
References in corpus (6)
- Cavity Optomechanics
- Extremely Low Loss Phonon-Trapping Cryogenic Acoustic Cavities for Future Physical Experiments
- Hybrid quantum systems with trapped charged particles
- Acoustic tests of Lorentz symmetry using quartz oscillators
- Observation of the Fundamental Nyquist Noise Limit in an Ultra-High -Factor Cryogenic Bulk Acoustic Wave Cavity
- Measurements of Elastic Properties of Langatate at Liquid Helium Temperatures for design of ultra low loss mechanical systems