Cascading Failures in AC Electricity Grids
arXiv:1604.06733 · doi:10.1103/PhysRevE.94.032209
Abstract
Sudden failure of a single transmission element in a power grid can induce a domino effect of cascading failures, which can lead to the isolation of a large number of consumers or even to the failure of the entire grid. Here we present results of the simulation of cascading failures in power grids, using an alternating current (AC) model. We first apply this model to a regular square grid topology. For a random placement of consumers and generators on the grid, the probability to find more than a certain number of unsupplied consumers decays as a power law and obeys a scaling law with respect to system size. Varying the transmitted power threshold above which a transmission line fails does not seem to change the power law exponent . Furthermore, we study the influence of the placement of generators and consumers on the number of affected consumers and demonstrate that large clusters of generators and consumers are especially vulnerable to cascading failures. As a real-world topology we consider the German high-voltage transmission grid. Applying the dynamic AC model and considering a random placement of consumers, we find that the probability to disconnect more than a certain number of consumers depends strongly on the threshold. For large thresholds the decay is clearly exponential, while for small ones the decay is slow, indicating a power law decay.
arXiv commentsubmitted to Phys. Rev. E, 7 pages, 7 figures
References in corpus (14)
- Cascade-based attacks on complex networks
- Analysis of a power grid using the Kuramoto-like model
- Comparative analysis of existing models for power-grid synchronization
- Sandpile on Scale-Free Networks
- Dynamic Effects Increasing Network Vulnerability to Cascading Failures
- Transport in Sand Piles, Interface Depinning, and Earthquake Models
- Impact of network topology on synchrony of oscillatory power grids
- The Impact of the Topology on Cascading Failures in Electric Power Grids
- Numerical Determination of the Avalanche Exponents of the Bak-Tang-Wiesenfeld Model
- Nonlocal effects and counter measures in cascading failures
- Nonlocal failures in complex supply networks by single link additions
- Multistability of Phase-Locking and Topological Winding Numbers in Locally Coupled Kuramoto Models on Single-Loop Networks
- Long-range Response in AC Electricity Grids
- Long-Range Response to Transmission Line Disturbances in DC Electricity Grids
Cited by in corpus (12)
- Dynamically induced cascading failures in power grids
- Non-Local Impact of Link Failures in Linear Flow Networks
- Transient chaos enforces uncertainty in the British power grid
- Dynamical modelling of cascading failures in the Turkish power grid
- On structural and dynamical factors determining the integrated basin instability of power-grid nodes
- Modal Decomposition of the Linear Swing Equation in Networks with Symmetries
- Bridging between Load-Flow and Kuramoto-like Power Grid Models: A Flexible Approach to Integrating Electrical Storage Units
- Analysis of the Dynamics and Topology Dependencies of Small Perturbations in Electric Transmission Grids
- Decreased resilience in power grids under dynamically induced vulnerabilities
- Evolving Powergrids in Self-Organized Criticality: An analogy with Sandpile and Earthquakes
- Optimal location of reinforced inertia to stabilize power grids
- The Waiting-Time Distribution for Network Partitions in Cascading Failures in Power Networks