Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI
arXiv:1603.00040 · doi:10.1109/TMI.2009.2023119
Abstract
In radial fast spin-echo MRI, a set of overlapping spokes with an inconsistent T2 weighting is acquired, which results in an averaged image contrast when employing conventional image reconstruction techniques. This work demonstrates that the problem may be overcome with the use of a dedicated reconstruction method that further allows for T2 quantification by extracting the embedded relaxation information. Thus, the proposed reconstruction method directly yields a spin-density and relaxivity map from only a single radial data set. The method is based on an inverse formulation of the problem and involves a modeling of the received MRI signal. Because the solution is found by numerical optimization, the approach exploits all data acquired. Further, it handles multi-coil data and optionally allows for the incorporation of additional prior knowledge. Simulations and experimental results for a phantom and human brain in vivo demonstrate that the method yields spin-density and relaxivity maps that are neither affected by the typical artifacts from TE mixing, nor by streaking artifacts from the incomplete k-space coverage at individual echo times.
25 pages, 6 figures, 2 tables. Copyright 2009 IEEE
Cited by in corpus (16)
- Magnetization Transfer in Magnetic Resonance Fingerprinting
- Fast T2 Mapping with Improved Accuracy Using Undersampled Spin-echo MRI and Model-based Reconstructions with a Generating Function
- On the reconstruction of block-sparse signals with an optimal number of measurements
- Physics-based Reconstruction Methods for Magnetic Resonance Imaging
- Model-Based Reconstruction for Simultaneous Multi-Slice T1 Mapping using Single-Shot Inversion-Recovery Radial FLASH
- Computational MRI with Physics-based Constraints: Application to Multi-contrast and Quantitative Imaging
- Quantitative Magnetic Resonance Imaging by Nonlinear Inversion of the Bloch Equations
- Free-Breathing Myocardial T1 Mapping using Inversion-Recovery Radial FLASH and Motion-Resolved Model-Based Reconstruction
- Free-Breathing Liver Fat, and Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-based Reconstruction
- Joint T1 and T2 Mapping with Tiny Dictionaries and Subspace-Constrained Reconstruction
- Time efficiency analysis for undersampled quantitative MRI acquisitions
- Latent Signal Models: Learning Compact Representations of Signal Evolution for Improved Time-Resolved, Multi-contrast MRI
- Rapid, High-resolution and Distortion-free Mapping of Fetal Brain using Multi-echo Radial FLASH and Model-based Reconstruction
- A Probabilistic Bayesian Approach to Recover map and Phase Images for Quantitative Susceptibility Mapping
- Rational Approximation of Golden Angles: Accelerated Reconstructions for Radial MRI
- Fast Whole-Brain MR Multi-Parametric Mapping with Scan-Specific Self-Supervised Networks