Multi-Material 3-D Viscoelastic Model of a Transtibial Residuum from In-vivo Indentation and MRI Data
arXiv:1602.08956 · doi:10.1016/j.jmbbm.2016.02.020
Abstract
Although the socket is critical in a prosthetic system for a person with limb amputation, the methods of its design are largely artisanal. A roadblock for a repeatable and quantitative socket design process is the lack of predictive and patient specific biomechanical models of the residuum. This study presents the evaluation of such a model using a combined experimental-numerical approach. The model geometry and tissue boundaries are derived from MRI. The soft tissue non-linear elastic and viscoelastic mechanical behavior was evaluated using inverse finite element analysis (FEA) of in-vivo indentation experiments. A custom designed robotic in-vivo indentation system was used to provide a rich experimental data set of force versus time at 18 sites across a limb. During FEA, the tissues were represented by two layers, namely the skin-adipose layer and an underlying muscle-soft tissue complex. The non-linear elastic behavior was modeled using 2nd order Ogden hyperelastic formulations, and viscoelasticity was modeled using the quasi-linear theory of viscoelasticity. To determine the material parameters for each tissue, an inverse FEA based optimization routine was used that minimizes the combined mean of the squared force differences between the numerical and experimental force-time curves for indentations at 4 distinct anatomical regions on the residuum. The optimization provided the following material parameters for the skin-adipose layer: c=5.22 kPa, m=4.79, gamma=3.57 MPa, tau=0.32 s and for the muscle-soft tissue complex: c=5.20 kPa, m=4.78, gamma=3.47 MPa, tau=0.34 s. These parameters were evaluated to predict the force-time curves for the remaining 14 anatomical locations. The mean percentage error (mean absolute error/ maximum experimental force) for these predictions was 7 +/- 3%. The mean percentage error at the 4 sites used for the optimization was 4%.
References in corpus (4)
- Digital image correlation and finite element modelling as a method to determine mechanical properties of human soft tissue in vivo
- Control of Tension-Compression Asymmetry in Ogden Hyperelasticity with Application to Soft Tissue Modelling
- Validation of Continuously Tagged MRI for the Measurement of Dynamic 3D Skeletal Muscle Tissue Deformation
- Validation of SPAMM Tagged MRI Based Measurement of 3D Soft Tissue Deformation
Cited by in corpus (4)
- Constitutive parameter identification of transtibial residual limb soft tissue using ultrasound indentation and shear wave elastography
- 3D Ultrasound Shear Wave Elastography for Musculoskeletal Tissue Assessment Under Compressive Load: A Feasibility Study
- Lower leg compression and its biomechanical effects on the soft tissues of the leg
- Comparison of mechanical conditions in a lower leg model with 5 or 6 tissue types while exposed to prosthetic sockets applying finite element analysis