Specific heat measurement of thin suspended SiN membrane from 8 K to 300 K using the 3-Vlklein method
arXiv:1511.07606 · doi:10.1063/1.4821501
Abstract
We present a specific heat measurement technique adapted to thin or very thin suspended membranes from low temperature (8 K) to 300 K. The presented device allows the measurement of the heat capacity of a 70 ng silicon nitride membrane (50 or 100 nm thick), corresponding to a heat capacity of 1.4x10 J/K at 8 K and 5.1x10 J/K at 300 K. Measurements are performed using the 3 method coupled to the Vlklein geometry. This configuration allows the measurement of both specific heat and thermal conductivity within the same experiment. A transducer (heater/thermometer) is used to create an oscillation of the heat flux on the membrane; the voltage oscillation appearing at the third harmonic which contains the thermal information is measured using a Wheatstone bridge set-up. The heat capacity measurement is performed by measuring the variation of the 3 voltage over a wide frequency range and by fitting the experimental data using a thermal model adapted to the heat transfer across the membrane. The experimental data are compared to a regular Debye model; the specific heat exhibits features commonly seen for glasses at low temperature.
References in corpus (5)
- Phonons in Slow Motion: Dispersion Relations in Ultra-Thin Si Membranes
- Phonon Heat Conduction in Corrugated Silicon Nanowires Below the Casimir Limit
- Highly sensitive thermal conductivity measurements of suspended membranes (SiN and diamond) using a 3w-Volklein method
- Membrane-based nanocalorimeter for high-resolution measurements of low-temperature specific heat
- Topology effects on the heat capacity of mesoscopic superconducting disks
Cited by in corpus (5)
- The thermal conductivity of silicon nitride membranes is not sensitive to stress
- A short account of thermoelectric film characterization techniques
- Crossover in the electron-phonon heat exchange in layered nanostructures
- Quantum and thermal fluctuations of a thin elastic plate
- Simultaneous measurement of thermal conductivity and specific heat in quasi-two-dimensional membranes using the 3ω method