Abstract
We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator before capturing on a He nucleus in the proportional counters. Segmentation improves neutron energy reconstruction while the large volume of scintillator increases sensitivity to low neutron fluxes. A main goal of its design is to study comparatively low neutron fluxes, such as cosmogenic neutrons at the Earth's surface, in an underground environment, or from low-activity neutron sources. In this paper, we present details of its design and construction as well as its characterization with a calibrated Cf source and monoenergetic neutron fields of 2.5 MeV and 14 MeV. Detected monoenergetic neutron spectra are unfolded using a Singular Value Decomposition method, demonstrating a 5% energy resolution at 14 MeV. Finally, we discuss plans for measuring the surface and underground cosmogenic neutron spectra with FaNS-2.
20 pages, 13 figures, Submitted to JINST
References in corpus (10)
- Dark Matter Results from 225 Live Days of XENON100 Data
- Measurement of the solar neutrino capture rate with gallium metal. III: Results for the 2002--2007 data-taking period
- Measurement of the half-life of the two-neutrino double beta decay of Ge-76 with the Gerda experiment
- Characterization of a Li-6 loaded liquid organic scintillator for fast neutron spectrometry and thermal neutron detection
- Background Radiation Measurements at High Power Research Reactors
- Low-Background gamma counting at the Kimballton Underground Research Facility
- Measuring Muon-Induced Neutrons with Liquid Scintillation Detector at Soudan Mine
- Neutron spectrometer for fast nuclear reactors
- Fast Neutron Detection with a Segmented Spectrometer
- Improved Fast Neutron Spectroscopy via Detector Segmentation