High accuracy CO line intensities determined from theory and experiment
arXiv:1510.05105 · doi:10.1103/PhysRevLett.114.243001
Abstract
Atmospheric CO concentrations are being closely monitored by remote sensing experiments which rely on knowing line intensities with an uncertainty of 0.5\%\ or better. Most available laboratory measurements have uncertainties much larger than this. We report a joint experimental and theoretical study providing rotation-vibration line intensities with the required accuracy. The {\it ab initio} calculations are extendible to all atmospherically important bands of CO and to its isotologues. As such they will form the basis for detailed CO spectroscopic line lists for future studies.
arXiv comment5 pages, 2 figures, 1 table
Cited by in corpus (26)
- ExoMol Molecular linelists -- XXXIII. The spectrum of Titanium Oxide
- ExoMol molecular line lists - XVI: The rotation-vibration spectrum of hot HS
- The 2020 release of the ExoMol database: molecular line lists for exoplanet and other hot atmospheres
- ExoMol line lists -- XXXIX. Ro-vibrational molecular line list for CO
- ExoMol molecular line lists - XIV: The rotation-vibration spectrum of hot SO
- Accurate frequency referencing for fieldable dual-comb spectroscopy
- A room temperature CO line list with ab initio computed intensities
- Uncertainty Estimates for Theoretical Atomic and Molecular Data
- ExoMol molecular line lists - XXIII: spectra of PO and PS
- Perspective: Accurate ro-vibrational calculations on small molecules
- Room temperature line lists for CO\2 symmetric isotopologues with \textit{ab initio} computed intensities
- Laboratory spectra of hot molecules: data needs for hot super-Earth exoplanets
- Radiative lifetimes and cooling functions for astrophysically important molecules
- Sub-promille measurements and calculations of CO (3--0) overtone line intensities
- ExoMol molecular line lists - XVII The rotation-vibration spectrum of hot SO
- Cavity ring-down spectroscopy of CO near = 2.06 m: Accurate transition intensities for the Orbiting Carbon Observatory-2 (OCO-2) "strong band"
- Ab initio Calculation of Fluid Properties for Precision Metrology
- High accuracy water potential energy surface for the calculation of infrared spectra
- Potential energy surface, dipole moment surface and the intensity calculations for the 10 micron, 5 micron, and 3 micron bands of ozone
- Correcting photodetector nonlinearity in dual-comb interferometry
- A variationally computed room temperature line list for AsH
- Linear probing of molecules at micrometric distances from a surface with sub-Doppler frequency resolution
- Accurate prediction of HO and DO sensitivity coefficients to probe a variable proton-to-electron mass ratio
- Empirical normal intensity distribution for overtone vibrational spectra of triatomic molecules
- Use of the complete basis set limit for computing highly accurate ab initio dipole moments
- Cavity buildup dispersion spectroscopy