High accuracy CO line intensities determined from theory and experiment
arXiv:1510.05105 · doi:10.1103/PhysRevLett.114.243001
Abstract
Atmospheric CO concentrations are being closely monitored by remote sensing experiments which rely on knowing line intensities with an uncertainty of 0.5\%\ or better. Most available laboratory measurements have uncertainties much larger than this. We report a joint experimental and theoretical study providing rotation-vibration line intensities with the required accuracy. The {\it ab initio} calculations are extendible to all atmospherically important bands of CO and to its isotologues. As such they will form the basis for detailed CO spectroscopic line lists for future studies.
5 pages, 2 figures, 1 table
Cited by in corpus (26)
- ExoMol Molecular linelists -- XXXIII. The spectrum of Titanium Oxide
- ExoMol molecular line lists - XVI: The rotation-vibration spectrum of hot HS
- The 2020 release of the ExoMol database: molecular line lists for exoplanet and other hot atmospheres
- ExoMol line lists -- XXXIX. Ro-vibrational molecular line list for CO
- ExoMol molecular line lists - XIV: The rotation-vibration spectrum of hot SO
- Accurate frequency referencing for fieldable dual-comb spectroscopy
- A room temperature CO line list with ab initio computed intensities
- Uncertainty Estimates for Theoretical Atomic and Molecular Data
- ExoMol molecular line lists - XXIII: spectra of PO and PS
- Perspective: Accurate ro-vibrational calculations on small molecules
- Room temperature line lists for CO\2 symmetric isotopologues with \textit{ab initio} computed intensities
- Laboratory spectra of hot molecules: data needs for hot super-Earth exoplanets
- Radiative lifetimes and cooling functions for astrophysically important molecules
- Sub-promille measurements and calculations of CO (3--0) overtone line intensities
- ExoMol molecular line lists - XVII The rotation-vibration spectrum of hot SO
- Cavity ring-down spectroscopy of CO near = 2.06 m: Accurate transition intensities for the Orbiting Carbon Observatory-2 (OCO-2) "strong band"
- Ab initio Calculation of Fluid Properties for Precision Metrology
- High accuracy water potential energy surface for the calculation of infrared spectra
- Potential energy surface, dipole moment surface and the intensity calculations for the 10 micron, 5 micron, and 3 micron bands of ozone
- Correcting photodetector nonlinearity in dual-comb interferometry
- A variationally computed room temperature line list for AsH
- Linear probing of molecules at micrometric distances from a surface with sub-Doppler frequency resolution
- Accurate prediction of HO and DO sensitivity coefficients to probe a variable proton-to-electron mass ratio
- Empirical normal intensity distribution for overtone vibrational spectra of triatomic molecules
- Use of the complete basis set limit for computing highly accurate ab initio dipole moments
- Cavity buildup dispersion spectroscopy