Performance of a SensL-30035-16P Silicon Photomultiplier array at liquid argon temperature
arXiv:1505.07261 · doi:10.1088/1748-0221/10/08/P08013
Abstract
Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite will be the reduction of radiogenic background sources to negligible levels. This is only possible if ultra pure high efficiency photosensors are available for the scintillation light readout. Current experiments (e.g. Xenon, LUX, Darkside, ArDM) use cryogenic PMTs as photosensors. An attractive alternative is represented by silicon photomultiplier arrays (SiPM arrays), which show unrivalled performances in single photon detection. This paper reports on the performance of the SensL-30035-16P SiPM array and a custom made cryogenic front-end board at the liquid argon temperature.
arXiv comment12 pages, 12 figures
References in corpus (4)
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
- Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
- Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
Cited by in corpus (5)
- A low-energy sensitive compact gamma-ray detector based on LaBr3 and SiPM for GECAM
- First operation of undoped CsI directly coupled with SiPMs at 77 Kelvin
- Cryogenic readout for multiple VUV4 Multi-Pixel Photon Counters in liquid xenon
- The GAP-TPC
- On the Evaluation of Silicon Photomultipliers for Use as Photosensors in Liquid Xenon Detectors