Suppression of parametric oscillatory instability in third generation gravitational wave detectors
arXiv:1503.06773 · doi:10.1016/j.physleta.2015.04.033
Abstract
We discuss one possible method for suppression of the nonlinear effect of a parametric oscillatory instability in a Fabry-Perot cavity of the next generation of gravitational wave detectors by determination of optimal radii of curvature of interferometers' mirrors. Varying the radii of curvature of the mirrors we can change the frequencies of the optical modes of the Fabry-Perot resonators and distributions of optical fields in optical modes, which, in turn, can change the number of unstable modes, leading to parametric oscillatory instability. The determination of the optimal values of the radii of curvature of mirrors to reduce the number of unstable modes by thermal lensing is fulfilled.
arXiv comment6 pages, 1 figure, 2 tables
References in corpus (6)
- Parametric Oscillatory Instability in Fabry-Perot (FP) Interferometer
- Analysis of Parametric Oscillatory Instability in Power Recycled LIGO Interferometer
- Parametric instabilities and their control in advanced interferometer GW detectors
- A General Approach to Optomechanical Parametric Instabilities
- Observation of the Three-Mode Parametric Instability
- Analysis of parametric oscillatory instability in Fabry-Perot cavity with Gauss and Laguerre-Gauss main mode profile