Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction
arXiv:1503.00688 · doi:10.1109/TBME.2015.2406332
Abstract
Goal: A new method for heart rate monitoring using photoplethysmography (PPG) during physical activities is proposed. Methods: It jointly estimates spectra of PPG signals and simultaneous acceleration signals, utilizing the multiple measurement vector model in sparse signal recovery. Due to a common sparsity constraint on spectral coefficients, the method can easily identify and remove spectral peaks of motion artifact (MA) in PPG spectra. Thus, it does not need any extra signal processing modular to remove MA as in some other algorithms. Furthermore, seeking spectral peaks associated with heart rate is simplified. Results: Experimental results on 12 PPG datasets sampled at 25 Hz and recorded during subjects' fast running showed that it had high performance. The average absolute estimation error was 1.28 beat per minute and the standard deviation was 2.61 beat per minute. Conclusion and Significance: These results show that the method has great potential to be used for PPG-based heart rate monitoring in wearable devices for fitness tracking and health monitoring.
Published in IEEE Transactions on Biomedical Engineering, Vol. 62, No. 8, PP. 1902-1910, August 2015
References in corpus (2)
Cited by in corpus (13)
- Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise with Simultaneous Accelerometry
- Improving Photoplethysmographic Measurements under Motion Artifacts using Artificial Neural Network for Personal Healthcare
- A Time-Frequency Domain Approach of Heart Rate Estimation From Photoplethysmographic (PPG) Signal
- SPECMAR: Fast Heart Rate Estimation from PPG Signal using a Modified Spectral Subtraction Scheme with Composite Motion Artifacts Reference Generation
- Robust and Energy-efficient PPG-based Heart-Rate Monitoring
- Improving Heart Rate Estimation on Consumer Grade Wrist-Worn Device Using Post-Calibration Approach
- HeartBEAT: Heart Beat Estimation through Adaptive Tracking
- Monash University, UEA, UCR Time Series Extrinsic Regression Archive
- How nonlinear-type time-frequency analysis can help in sensing instantaneous heart rate and instantaneous respiratory rate from photoplethysmography in a reliable way
- A Survey of Challenges and Opportunities in Sensing and Analytics for Cardiovascular Disorders
- A machine learning method correlating pulse pressure wave data with pregnancy
- Performance Analysis of Joint-Sparse Recovery from Multiple Measurements and Prior Information via Convex Optimization
- Supervised Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise without Simultaneous Acceleration Signals