Single pulse and profile variability study of PSR J1022+1001
arXiv:1502.06785 · doi:10.1093/mnras/stv397
Abstract
Millisecond pulsars (MSPs) are known as highly stable celestial clocks. Nevertheless, recent studies have revealed the unstable nature of their integrated pulse profiles, which may limit the achievable pulsar timing precision. In this paper, we present a case study on the pulse profile variability of PSR J1022+1001. We have detected approximately 14,000 sub-pulses (components of single pulses) in 35-hr long observations, mostly located at the trailing component of the integrated profile. Their flux densities and fractional polarisation suggest that they represent the bright end of the energy distribution in ordinary emission mode and are not giant pulses. The occurrence of sub-pulses from the leading and trailing components of the integrated profile is shown to be correlated. For sub-pulses from the latter, a preferred pulse width of approximately 0.25 ms has been found. Using simultaneous observations from the Effelsberg 100-m telescope and the Westerbork Synthesis Radio Telescope, we have found that the integrated profile varies on a timescale of a few tens of minutes. We show that improper polarisation calibration and diffractive scintillation cannot be the sole reason for the observed instability. In addition, we demonstrate that timing residuals generated from averages of the detected sub-pulses are dominated by phase jitter, and place an upper limit of ~700 ns for jitter noise based on continuous 1-min integrations.
13 pages, 20 figures, 3 tables, accepted for publication in MNRAS
References in corpus (11)
- Shapiro delay measurement of a two solar mass neutron star
- A Massive Pulsar in a Compact Relativistic Binary
- The ATNF Pulsar Catalogue
- TEMPO2, a new pulsar timing package. I: Overview
- Tests of general relativity from timing the double pulsar
- PSRCHIVE and PSRFITS An Open Approach to Radio Pulsar Data Storage and Analysis
- The relativistic pulsar-white dwarf binary PSR J1738+0333 II. The most stringent test of scalar-tensor gravity
- Dispersion Measure Variations and their Effect on Precision Pulsar Timing
- High-fidelity radio astronomical polarimetry using a millisecond pulsar as a polarized reference source
- Timing, polarimetry and physics of the bright, nearby millisecond pulsar PSR J0437-4715 - a single-pulse perspective
- Improving the precision of pulsar timing through polarization statistics
Cited by in corpus (9)
- The disturbance of a millisecond pulsar magnetosphere
- Measurements of pulse jitter and single-pulse variability in millisecond pulsars using MeerKAT
- Variability, polarimetry, and timing properties of single pulses from PSR J1713+0747 using the Large European Array for Pulsars
- Toward an Empirical Theory of Pulsar Emission XII: Exploring the Physical Conditions in Millisecond Pulsar Emission Regions
- The Statistics of Radio Astronomical Polarimetry: Disjoint, Superposed, and Composite Samples
- Highly polarized components of integrated pulse profiles
- Variability, polarimetry, and timing properties of single pulses from PSR J2222-0137 using FAST
- Deciphering Profile Stability in Millisecond Pulsars: Timescales, Frequency Evolution, and Implications on Emission Mechanisms
- Constraining the selection corrected luminosity function and total pulse count for radio transients