Abstract
An increasing number of measurements in fundamental and applied physics rely on magnetically shielded environments with sub nano-Tesla residual magnetic fields. State of the art magnetically shielded rooms (MSRs) consist of up to seven layers of high permeability materials in combination with highly conductive shields. Proper magnetic equilibration is crucial to obtain such low magnetic fields with small gradients in any MSR. Here we report on a scheme to magnetically equilibrate MSRs with a 10 times reduced duration of the magnetic equilibration sequence and a significantly lower magnetic field with improved homogeneity. For the search of the neutron's electric dipole moment, our finding corresponds to a linear improvement in the systematic reach and a 40 % improvement of the statistical reach of the measurement. However, this versatile procedure can improve the performance of any MSR for any application.
5 pages, 4 figures
References in corpus (3)
Cited by in corpus (10)
- Electric Dipole Moments of the Atoms, Molecules, Nuclei and Particles
- A large-scale magnetic shield with 10^6 damping at mHz frequencies
- Optimal Inverse Design of Magnetic Field Profiles in a Magnetically Shielded Cylinder
- Methods for measuring the electron EDM using ultracold YbF molecules
- The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements
- The PanEDM Neutron Electric Dipole Moment Experiment at the ILL
- The Development of the NNBAR Experiment
- Sensitivity of Fields Generated within Magnetically Shielded Volumes to Changes in Magnetic Permeability
- INTENTAS -- An entanglement-enhanced atomic sensor for microgravity
- Low-noise environment for probing fundamental symmetries