Test and characterization of a prototype silicon-tungsten electromagnetic calorimeter
arXiv:1407.5724 · doi:10.1016/j.nima.2014.07.019
Abstract
New generation high-energy physics experiments demand high precision tracking and accurate measurements of a large number of particles produced in the collisions of lementary particles and heavy-ions. Silicon-tungsten (Si-W) calorimeters provide the most viable technological option to meet the requirements of particle detection in high multiplicity environments. We report a novel Si-W calorimeter design, which is optimized for discrimination up to high momenta. In order to test the feasibility of the calorimeter, a prototype mini-tower was constructed using silicon pad detector arrays and tungsten layers. The performance of the mini-tower was tested using pion and electron beams at the CERN Proton Synchrotron (PS). The experimental results are compared with the results from a detailed GEANT-4 simulation. A linear relationship between the observed energy deposition and simulated response of the mini-tower has been obtained, in line with our expectations.
13 figures, represents test beam data with PS beam line at CERN
References in corpus (3)
Cited by in corpus (5)
- Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter
- A wide swing charge sensitive amplifier for a prototype Si-W EM calorimeter
- Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter