Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification
arXiv:1405.3023 · doi:10.1088/0957-0233/25/11/115301
Abstract
In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations. In addition, the notion of a valid measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an outlier measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to robust uncertainty estimation models, which are tested against both synthetic benchmark data as well as actual experimental measurements. For all cases considered here, standard uncertainties are estimated at the 68.5% confidence level while expanded uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical values thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements.
Cited by in corpus (7)
- Volumetric Particle Tracking Velocimetry (PTV) Uncertainty Quantification
- Two Regime Cooling in Flow Induced by a Spark Discharge
- Uncertainty amplification due to density/refractive-index gradients in volumetric PTV and BOS experiments
- On the micro PIV accuracy and reliability utilizing suspension particles of large, non-Gaussian particle image
- Meta-Uncertainty for Particle Image Velocimetry
- Uncertainty-based pressure field reconstruction from PIV/PTV flow measurements with generalized least-squares
- A High Precision Time Measurement Method Based on Frequency-domain Phase-Fitting for Nuclear Pulse Detection